Groundgridterrain fit bench

Compare terrain module sizes across tables and storage.

Choose a size for one reusable collection. Check each table format, then see whether all required modules fit your available cases or shelves.

Comparison rules

Storage clearance is reserved at each horizontal side and above the top layer, not between modules. Allow extra space for padding in your measured dimensions. Set minimum coverage to 100% if every tabletop must be fully covered.

Alternative table formats

Use one table setup at a time. The same collection is reused across formats.

Table 1
Table 2
2 of 6 rows

Storage available together

Enter free interior dimensions, after fixed obstructions. Each row is one physical case or shelf space.

Storage unit 1
Storage unit 2
2 of 6 rows

Module sizes to compare

Each candidate represents its own same-size collection. Use the full stored height, including fixed scenery.

Candidate 1
Candidate 2
2 of 6 rows

Best under your chosen preference: 30 × 20 modules.

1 of 2 candidates meet every table's minimum coverage and height, the collection ceiling and combined storage capacity. Preference: highest worst-table coverage, then fewer modules.

CandidateReusable modulesWorst-table coverageStorage capacityResult
30 × 20 modules12100%12Meets constraints
30 × 30 modules8100%4Does not meet constraints
30 × 20 modules: layouts, storage and reasons

All entered constraints pass. Check physical clearances and safe stacking before building.

Reusable collection: 12 modules, the largest single-table grid below, not the sum. Each table is an alternative setup.

Table formats — coverage uses the original full tabletop area
TableOrientationGridModulesCoverageUncovered areaUnused usable edges
Large tableas-entered4 × 312100% — full0 cm²0 × 0 cm
Small tableas-entered3 × 39100% — full0 cm²0 × 0 cm
Available storage units together — stacking allowed by you
UnitOrientationGrid per layerLayer capacityCapacityAssignedUsed height
Case Aas-entered2 × 228816 cm
Case Bas-entered2 × 124416 cm

Unplaced: 0. Storage is assigned in entered unit order. Each candidate is a separate hypothetical collection.

30 × 30 modules: layouts, storage and reasons
  • Storage shortfall: 4 modules.

Reusable collection: 8 modules, the largest single-table grid below, not the sum. Each table is an alternative setup.

Table formats — coverage uses the original full tabletop area
TableOrientationGridModulesCoverageUncovered areaUnused usable edges
Large tableas-entered4 × 28100% — full0 cm²0 × 0 cm
Small tableas-entered3 × 26100% — full0 cm²0 × 0 cm
Available storage units together — stacking allowed by you
UnitOrientationGrid per layerLayer capacityCapacityAssignedUsed height
Case Aas-entered2 × 124416 cm
Case Bas-entered2 × 02000 cm

Unplaced: 4. Storage is assigned in entered unit order. Each candidate is a separate hypothetical collection.